| Flow Rate/Temperature Rise: |
6.2 gal/min (40°F rise), 5.0 gal/min (50°F rise)
4.1 gal/min (60°F rise), 3.5 gal/min (70°F rise)
3.1 gal/min (80°F rise)
|
| Ignition |
High Voltage Discharge Spark
|
| Efficiency |
87.1% AFUE rating
|
| Fuel Consumption: |
1.05 gal/h
|
| Capacity of Heat Exchanger: |
5.10 gal
|
| Temperature Differential Settings: |
3.6°F, 18°F, 36°F (3 settings by selector switch)
|
| Fuel System: |
External tank***
|
| Dimensions (W x H x D): |
12-5/8" x 27-3/4" x 22-1/2"
|
| Weight: |
81 lbs. Empty
|
| Vent Pipe Hole: |
4-3/4" diameter (for flue pipe installation kit)
|
| Maximum Length of Vent Pipe System: |
10 ft., 3 bends or less (exhaust pipes for flue pipe installation kit)
|
| Electrical Rating: |
120 Volts AC, 60 Hz Ignition - 120W Burning - 98W
|
| Fuel Type: |
ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 FUEL OIL
ASTM D975 ULTRA LOW SULPHUR DEISEL (ULSD)
ASTM D396 No.2 Fuel OIL (HOME HEATING OIL)
|
| Required Accessories: |
Flue Pipe Installation Kit or 5-inch Chimney Adapter Kit Fuel Filter and Drain Valve
|
| Safety Device: |
High Limit Thermistor, Heat Exchanger Bi-metal Switch, Temperature Fuse, Fusible Link Valve
Exhaust Air Temperature: less than 500°F Temp & Pressure Relief Valve (included)
|
| Nozzle Size: |
0.85 GPH
|
| Spraying Angle: |
60°
|
| Spray Pattern: |
Delavan Type XA
|
| Temperature Fuse: |
282°F
|
| Electric Current Fuse: |
5 A (Main Control) 7 A (Auxiliary Port for Circulation Pump., etc.)
|
| Optional Accessories: |
Remote Controller
|